Health Service Modules Event ID 11903

In momentul actual ma ocup in firma de administrarea a 4 infrastructuri de SCOM. Primul lucru pe care incerc sa il fac e sa nu am nici o eroare in event-ul de Operations Manager. Un vis destul de mare… :) Dar hai sa incep cu un event pe care l-am gasit. Acesta este

Event Type: Error
Event Source: Health Service Modules
Event Category: None
Event ID: 11903
User:  N/A
Computer: <<Server>>
Description: The Microsoft Operations Manager Expression Filter Module could not convert the received value to the requested type.
Property Expression: 3,75
Property Value: 3,75
Conversion Type: DataItemElementTypeDouble(3)
Original Error: 0x80FF005A
One or more workflows were affected by this. 
Workflow name: UIGeneratedMonitor6cb26ffe359143efb3bd4d30674af57f
Instance name: D:
Instance ID: {9240E1FD-9908-114C-1813-9D31D9367D36}
Management group: <<MGMGroup>>

Ce sa fie oare? Am cautat Workflow-ul care facea probleme. Era un monitor care masura spatiul pe disk in procente. Cand ma uit la overides… surpriza era pusa valoarea cu Virgula si dadea eroare. Dupa ce am schimbat valoarea sa fie cu punct … eroarea a disparut miraculos.

!Atentie:  Din cele citite cred ca depinde si de configurarea sitemului de operare din cadrul “Regional and Language Options”. In diferite tari virgula si punctul sunt schimbate in sensul pe care il dau la numere.